FellowsBecker906

Från Wiki
Hoppa till: navigering, sök

Charger : in numerous UPS systems due to the nature of their design another battery charger is employed, this is more common on sub 60kVA UPS systems and is extremely common on small sub 3kVA devices.

Battery : here is the energy storage section and is kept charged eith...

Rectifier : this part of the UPS converts the incoming alternating current (ac) supply to direct current (dc) and can offer charging current for the battery and also the supply requirements for the inverter.

Charger : in numerous UPS systems due to the character of their design a different battery charger is employed, this is more common on sub 60kVA UPS systems and is very common on small sub 3kVA models.

Battery : this is actually the energy storage area and is kept charged either by the rectifier or even a separate charger. As AH (ampere hour), which will be the amount of amperes of current that the battery can provide for an hour, their storage capacity is generally exhibited. There will be an amount of limiting facets depending upon the application, usually if the design calls for a small autonomy (period of time the battery will support its load for), the batteries could be cleared to a degree, in the case of emergency lighting where there is a need for a autonomy the battery won't be allowed to discharge so far. These circumstances help to permit the maximum design life of the battery to be performed.

Inverter : an ac output is provided by this section of the Uninterruptible power supply to the weight that is in phase with the input mains supply. Due to the quantity of conversions (ac to dc to ac) and the filtering involved it can be referred to as a 'clean source.'

Static Switch : this signal is as simple as a relay or even more generally using thyristors, its purpose is to switch the weight between the application mains supply and the inverter. As has been mentioned before the output of the inverter is in phase with the energy mains supply so that any switching between your two will be nearly seamless. This design helps to ensure that if the inverter activities an overload condition, because of its extremely fast over-current detection circuits it'll shift the load to the more sturdy mains supply. An average example would be each time a machine tray is switched on, the inrush current, based upon the size of one's uninterruptible power supplies, could cause the transfer to the utility mains supply, and once switched on the load can transfer back to the inverter giving the inverter has sufficient capacity to support the load. Also a mistake on the inverter will cause the load to be transferred, again practically seamlessly; it would be unusual for any loss of load that occurs over these circumstances.

Maintenance Bypass : more typically within UPS systems with a capacity of 6kVA or greater. The load is allowed by this arrangement to be transferred under controlled conditions to the utility mains and the UPS to be shut down without damage. Generally carried out for program UPS preservation or UPS fix.

External Maintenance Bypass : the installation of an maintenance bypass can allow the UPS to be removed/replaced without interruption to the load, also, if the true maintenance bypass is given from a separate source it can allow load screening in the case of a major UPS fix and/or checking of the autonomy under simulated load problems while the site load will be supported by the external maintenance bypass circuit. When allowing the UPS System to be bypassed onto standby diesel generator power this is often used. As an alternative, when batteries are removed and changed, it may only be achieved by putting the uniterruptible power into additional bypass. read more

Personliga verktyg